Chint Contactor

Mini Contactor

NC6 Mini Contactor-(06A, 09A)

  • The NC6 Series Mini Contactor is used in remote motor (≤4kW) control application.
  • Rating up to 690V, 9A (AC-3). —– (06A, 09A)
  • Standard: IEC/EN 60947-4-1
  • Two kinds of mounting available: Normal type (without pins); Pin type (with pins)
  • Ambient temp: -5℃~+40℃
  • Coil voltage (AC): 24V, 36V, 48V, 110V, 127V, 220V, 230V, 380V, 400V;
  • Auxiliary contacts: NCF6-20 & NCF6-02 (2NO or 2NC)
  • NCF6-13 & NCF6-31 (1NO & 3NC or 3NO & 1NC)
  • NCF6-40 & NCF6-04 (4NO or 4NC)
  • Assemble with Thermal Overload Relay NR2-11.5 to be a DOL Starter

NXRC Contactor Relay (Auxiliary Contactors)

The NXRC series contactor relay is used in relay control, signal transmission and isolation amplifier application

  • Standard: IEC/EN 60947-5-1
  • Ambient temp.: -35℃~+70℃
  • Rating up to 690V, Ith=10A

Top mounting auxiliary contacts:

  • Contact combination: 4NO or 3NO&1NC or 2NO&2NC or 1NO&3NC or 4NC

Coil Voltage:

  • AC: 24V, 36V, 48V, 110V, 127V, 220V, 380V, 415V (AC)
  • DC: 24V, 48V, 110V, 220V (DC)

NC1 Contactor and Overload Relay

NC1 Contactor (AC3 - 09A-95A)

  • The NC1 Series Contactor is used in remote motor (≤45kW) control application.
  • Rating up to 690V, 95A (AC-3). —– (09A, 12A, 18A, 25A, 32A, 40A, 50A, 65A, 80A, 95A)
  • Standard: IEC/EN 60947-4-1
  • Ambient temp: -25℃~+55℃
  • Coil voltage (AC): 24V, 36V, 48V, 110V, 127V, 220V, 230V,
  • 380V, 415V, 440V, 480V, 500V, 600V, 660V
  • Coil voltage (DC): 24V, 36V, 48V, 110V, 220;
  • Side & Top mounting auxiliary contacts
  • Top mounting time delay block: F5-T (making time delay); F5-D (breaking time delay)
  • Assemble with Thermal Overload Relay NR2 (or NRE8) to be a DOL Starter.
  • Assemble with another one & F4 & F5 & NR2 (or NRE8) to be a Star-Delta Starter Type QJX2;
  • Assemble with a current limiting block to be a Capacitor Contactor.
  • Assemble with another one to be a reversing contactor.

NC1-Z(N) DP Contactor (AC3 – 25A & 40A, 2N0+2NC Main Contacts, 48VDC Coil)

The NXRC series contactor relay is used in relay control, signal transmission and isolation amplifier application

Used for long-distance circuit making and breaking

  • Rated working voltage up to 690V, 25A and 40A (AC-3)
  • w/ 2 NO 2 NC main contacts
  • Compliance standards: IEC / EN 60947-4-1
  • Ambient air temperature: -25℃~+55℃,
  • Coil voltage: DC 48V
  • Can form into reversible contactor with other AC contactors
  • Standard: IEC/EN 60947-5-1
  • Ambient temp.: -35℃~+70℃
  • Rating up to 690V, Ith=10A

Top mounting auxiliary contacts:

  • Contact combination: 4NO or 3NO&1NC or 2NO&2NC or 1NO&3NC or 4NC

Coil Voltage:

  • AC: 24V, 36V, 48V, 110V, 127V, 220V, 380V, 415V (AC)
  • DC: 24V, 48V, 110V, 220V (DC)

NR2 Thermal Overload Relay

  • NR2 series thermal overload relay is used to provide overload and phase failure protection for AC motors.

    • Contacts: 1N0+1NC (Electrical separated / Potential Free)
    • Test / Hand & Self Reset
    • Rating up to 690V, 630A. —– (11.5A, 25A, 36A, 93A, 150A, 200A, 630A)
    • Standard: IEC/EN 60947-4-1
    • Ambient temp: -5℃~+40℃
    • NR2  Assemble with Contactor NC1, NC2, NC7 to be a DOL Starter.

NC2 Contactor and Overload Relay

NC2 Contactor (AC3- 115A to 800A)

  •  Rating up to 690V, 800A (AC-3) —– (115A,150A,185A,225A,265A,330A,400A,500A,630A,800A)
  • Standard: IEC/EN 60947-4-1
  • Ambient temp: -5℃~+40℃
  • Coil voltage (AC): 110V, 127V, 220V, 230V, 380V, 400V;
  • Top mounting auxiliary contacts: F4-20 & F4-02 & F4-11 (2NO or 2NC or 1NO & 1NC)
  • F4-13 & F4-31 (1NO & 3NC or 3NO & 1NC)
  • F4-40 & F4-04 & F4-22 (4NO or 4NC or 2NO & 2NC)
  • Top mounting time delay block: F5-T (making time delay); F5-D (breaking time delay)
  • Assemble with Thermal overload Relay NR2 to be a DOL Starter.
  • Assemble with another one to be a reversing contactor.

NR2 Thermal Overload Relay

NR2 series thermal overload relay is used to provide overload and phase failure protection for AC motors.

  • Contacts: 1N0+1NC (Electrical separated / Potential Free)
  • Test / Hand & Self Reset
  • Rating up to 690V, 630A. —– (11.5A, 25A, 36A, 93A, 150A, 200A, 630A)
  • Standard: IEC/EN 60947-4-1
  • Ambient temp: -5℃~+40℃
  • NR2  Assemble with Contactor NC1, NC2, NC7 to be a DOL Starter.

CJ19 Capacitor Switching Contactor

CJ19 Capacitor Switching Contactor (12.5 KVAR to 90 KVAR)

The CJ19 Series Contactor is used in remote capacitor (130kvar) switch application.

  • Rating up to 400V, 130A (AC-6b). —– (25A, 32A, 43A, 63A, 95A,115A,150A,170A)
  • Standard: IEC/EN 60947-4-1
  • Ambient temp: -5℃~+40℃
  • Coil voltage (AC): 24V, 36V, 48V, 110V, 127V, 220V, 230V, 380V, 415V, 440V, 480V, 500V
  • CJ19-25: Rating current 17A (AC-6b/380V);
  • Power of controlled capacitor≤12.5kvar.
  • CJ19-32: Rating current 23A (AC-6b/380V);
  • Power of controlled capacitor≤20kvar.
  • CJ19-43: Rating current 29A (AC-6b/380V);
  • Power of controlled capacitor≤25kvar.
  • CJ19-63: Rating current 43A (AC-6b/380V);
  • Power of controlled capacitor≤33.3kvar.
  • CJ19-95: Rating current 72.2A (AC-6b/400V);
  • Power of controlled capacitor≤50kvar.
  • CJ19-115: Rating current 87A (AC-6b/400V);
  • Power of controlled capacitor≤60kvar.
  • CJ19-150: Rating current 115A (AC-6b/400V);
  • Power of controlled capacitor≤80kvar.
  • CJ19-170: Rating current 130A (AC-6b/400V);
  • Power of controlled capacitor≤90kvar
    •  

MPCB
.

  • Rated Operational Voltage: 230V,415V,690VAC
  • Type NS25- Push Button and Type NS25X- Rotary Knob
  • Current Rating: (0.1-0.16A) to (20-25A)
  • NS280B –(16-25A) to (56-80A)
  • Accessories: Front or Side Aux Contacts
  • Fault signalling Contact, UVR,Shunt
  • Certification: CE / UL
  • Standard: IEC/EN-60947-2

NXC AC Contactor and Overload Relay

NXC AC Contactor (AC3- 6A to 630A) & NXC Mini Contactors (6A,9A,12A)

The NXC series AC contactor is used in remote motor (≤335kW) control application.

    • Rating up to 690V, 630A (AC-3). ——(6A, 9A, 12A, 16A, 18A, 22A, 25A, 32A, 38A, 40A, 50A, 65A, 75A, 85, 100A, 120A, 160A, 185A, 225A, 265A, 330A, 400A, 500A, 630A)
    • Standard: IEC/EN 60947-4-1
    • Ambient temp.: -35℃~+70℃
    • Coil voltage 6A~12A (mini type): 24V, 36V, 48V, 110V, 127V, 220V, 380V, 415V (AC)
    • Coil voltage AC : 6A~225A: 24V, 36V, 48V, 110V, 127V, 220V, 380V, 415V (AC)
    • Coil voltage AC/DC : 265A~630A: 24V, 36V, 48V, 110V, 127V, 220V, 380V, 415V (AC/DC)
    • Coil voltage DC: 24V, 48V, 110V, 220V (DC)
    • Side mounting and Top Mounted auxiliary contacts
    • Top mounting time delay block: F5-T (making time delay) & F5-D (breaking time delay)
    • Assemble with Thermal Overload Relay NXR to be a DOL Starter.
    • Assemble with another one to be a reversing contactor.

NXR Thermal Overload Relay

The NXR series thermal overload relay is used to provide overload and phase failure protection for AC Motors

  • Rating up to 690V, 630A (AC-3): —— (12A for mini type, 25A, 38A, 100A, 200A, 630A)
  • NXR-200 and NXR-630 are electronic overload relay.
  • Standard: IEC/EN 60947-5-1
  • Ambient temp.: -35℃~+70℃

Request For Quote

Prime Industrial Services is providing electrical goods and services to various sectors like Agriculture, Automobile, Automation, Construction, Health Care, Hotel, Paper, Pharmaceutical, Poultry, Power, Printing, Railway, Real Estate, Solar, Sugar, Telecom, Textile, Cement, Dairy, Film, Food , Processing, IT, Data centers, Mining, Shipping, Marine, Food & Beverages, Electronic, Control Panel Accessories etc.